Consistent reliability with accuracy.
Fixed or variable current sensitivity by Dip Switch selection
LEDās for visual indication of fault.
High Barrier connector at rear for easy termination and safety standards.
Tamper proof polycarbonate cover in the front.
Test & Reset Facility for testing healthiness of the relay
SKU: n/a
EARTH RESISTANCE TESTER
METRAVI ERT-1501 Digital Earthā¦
0 out of 5
(0)
SPECIFICATIONS
Range : 0Ī© to1000Ī©
Resolution :Ā 0.01Ī©
Accuracy : Ā±3%
DC Voltage Range : 0 V to 1000 V
AC Voltage Range : 0 V to 750 V
Resistance Range :Ā 0Ī© to 200kĪ©
Certifications :Ā CAT III 1000V,Ā CE
FEATURES
Data Hold facility
Displays test result and battery voltage on the same screen
LOCK Button for continuous HANDS FREE measurement
Both Earth Resistance and Earth Resistivity can be measured
Can be used in 4 Terminal and 3 Terminal configurations
Display : 4 Digits EXTRA LARGE Backlit Dual LCD Display
Earth Resistance Range : 0 ā 10/100/1000 Ohms
Complies with CE, CAT-III 1000V
Complete with Testing Kit
Re-Chargeable Battery and Battery Charger can be provided at extra cos
SKU: n/a
EARTH RESISTANCE TESTER
METRAVI ERT-1502 Digital Earthā¦
0 out of 5
(0)
SPECIFICATIONS
Range : 0-20/200/2000 Ī©
Resolution :Ā 0.01Ī©
Accuracy : Ā± 2%
DC Voltage Range : 0 V to 1000 V
AC Voltage Range : 0 V to 750 V
Resistance Range :Ā 0Ī© to 200kĪ©
Certifications :Ā CAT III 1000V,Ā CE
FEATURESĀ
Data Hold facility
Displays test result and battery voltage on the same screen
LOCK Button for continuous HANDS FREE measurement
Both Earth Resistance and Earth Resistivity can be measured
Can be used in 4 Terminal and 3 Terminal configurations
4 Digits EXTRA LARGE Backlit Dual LCD Display
SKU: n/a
PROBES
HIOKI P2000 DC High Voltage Prā¦
0 out of 5
(0)
SPECIFICATIONSĀ
Maximum Input Voltage : DC 2000 V
Maximum rated line-to-ground voltage
1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V
1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V
Input Resistance : 20 MĪ© Ā±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open)
Overload Protection :
2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L)
2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L)
Output Terminal : 4 mm banana terminal
Operating Temperature Range : -25Ā°C to 65Ā°C (-13Ā°F to 149Ā°F)
Operating Humidity Range : ā25Ā°C to 40Ā°C (ā13Ā°F to 104Ā°F): 80% RH or less (non-condensing)
40Ā°C to 65Ā°C (104Ā°F to 149Ā°F): Linearly reduces from 80% RH or less at 40Ā°C (104Ā°F) to 25% RH or less at 65Ā°C (149Ā°F) (non-condensing)
40Ā°C to 65Ā°C (104Ā°F to 149Ā°F): Linearly reduces from 80% RH or less at 40Ā°C (104Ā°F) to 25% RH or less at 65Ā°C (149Ā°F) (non-condensing)
Storage temperature and humidity range : -30Ā°C to 70Ā°C (-22Ā°F to 158Ā°F) 90% RH or less (non-condensing)
Standards : EN 61010
Included Accessories : Connection Cable Set L4943 Ć1, Strap with buckle Ć2, Strap Ć1, Carrying Case C0205 Ć1, Instruction Manual Ć1, Operating Precautions Ć1
FEATURES
Enables high voltage measurement up to CAT ā
¢ 2000 V
Safely measure solar installations like the mega-solar without interrupting the grid
Connects to compatible Hioki clamp meters and digital multimeters (DMMs)
ACCURACY FOR COMPATIBLE INSTRUMENTS
DT-4261 :
Range 600.0 V: Combined accuracy Ā±0.5% rdg Ā±0.2 V
Range 2000 V: Combined accuracy Ā±0.5% rdg Ā±5 V
Range 600.0 V: Combined accuracy Ā±0.5% rdg Ā±0.2 V
Range 2000 V: Combined accuracy Ā±0.5% rdg Ā±5 V
CM4141-50 ;Ā CM4371-50 ;Ā CM4373-50 ; CM4375-50 :
Range 600.0 V: Combined accuracy Ā±1.0% rdg Ā±0.3 V
Range 2000 V: Combined accuracy Ā±1.0% rdg Ā±3 V
Range 600.0 V: Combined accuracy Ā±1.0% rdg Ā±0.3 V
Range 2000 V: Combined accuracy Ā±1.0% rdg Ā±3 V
DT-4282 ; DT-4281 :
Range 60.000 V: Combined accuracy Ā±0.8% rdg Ā±0.002 V (output rate 1/10)
Range 600.00 V: Combined accuracy Ā±0.8% rdg Ā±0.02 V (output rate 1/10)
Range 60.000 V: Combined accuracy Ā±0.8% rdg Ā±0.002 V (output rate 1/10)
Range 600.00 V: Combined accuracy Ā±0.8% rdg Ā±0.02 V (output rate 1/10)
DT-4252 ; DT-4253 :
Range 60.00 V: Combined accuracy Ā±1.2% rdg Ā±0.05 V (output rate 1/10)
Range 600.0 V: Combined accuracy Ā±1.2% rdg Ā±0.5 V (output rate 1/10)
Range 60.00 V: Combined accuracy Ā±1.2% rdg Ā±0.05 V (output rate 1/10)
Range 600.0 V: Combined accuracy Ā±1.2% rdg Ā±0.5 V (output rate 1/10)
DT-4255 ; DT-4256 :
Range 60.00 V: Combined accuracy Ā±1.2% rdg Ā±0.03 V (output rate 1/10)
Range 600.0 V: Combined accuracy Ā±1.2% rdg Ā±0.3 V (output rate 1/10)
Range 60.00 V: Combined accuracy Ā±1.2% rdg Ā±0.03 V (output rate 1/10)
Range 600.0 V: Combined accuracy Ā±1.2% rdg Ā±0.3 V (output rate 1/10)
SKU: n/a
POWER SUPPLY
BEETECH 3005 30V DC REGULATED ā¦
0 out of 5
(0)
SPECIFICATION
TECHNICAL SPECIFICATION
Voltage output range : 0 ā 30V
Current output range : 0 ā 5A
Current and voltage display model : A means pointer display, D means LED display
Display precision Pointer display : Ā± 2.5%
Digital display : Ā± 1% Ā± 1 word
PARAMETER SPECIFICATION
Input voltage: AC 220V Ā± 10% (switch to choose) 50/60Hz
Operating condition :Ā -10ĖC ~ 40ĖC, ā¤ 90%RH
Storage condition : -10ĖC ~ 40ĖC, ā¤ 80%RH
Voltage stability : ā¤ 0.01% + 2mV
Load stability : ā¤ 0.01% + 2mV
Recovery time : ā¤ 100Āµs
Ripple and noise : ā¤ 1mVrms (effective value)
Temperature coefficient : ā¤ 200PPMĖC
FEATURES
DC Regulated Power Supply is an easy to use, low ripple high regulation precision instrument.
It is particularly suitable for experimental development and low voltage applications.
Its unique feature is over load protection, which makes it a safe power source for testing of electronic equipment.
The power supplyās output is floating i.e., either the positive or negative output is connected to the chasis or ground.
Thus the power supply may be used as a positive or negative DC source by grounding -ve or +ve terminal respectively.