PH Meter
HANNA HI98107 pHep Waterproof …
Hanna’s HI98107 pHep® pH tester displays readings with 0.1 pH resolution, ±0.1 pH accuracy, and a range from 0.0 to 14.0 pH. This rugged, reliable, ergonomic, pocket-sized tester is designed for use in the lab or fields while keeping things simple with a two-button operation.
- Extractable Cloth Junction to Extend pH Electrode Life
- Has Automatic Temperature Compensation
- For Use in Fresh Water
SKU: n/a -
BATTERY CAPACITY TESTER
HIOKI BATTERY TESTER BT3554-51
SPECIFICATIONS
- Resistance measurement range : 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges
- Accuracy : ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)
- Testing source frequency : 1 kHz ±30 Hz
- Voltage measurement range : ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges
- Temperature measurement accuracy : -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F)
- Absolute max. input voltage : 60 V DC max. (No AC input)
- Measurement time : 100 ms
- Response time : Approx. 1.6 sec.
- Power supply : LR6 (AA) Alkaline dry battery ×8
- Continuous operating time: About 8.3 hr. (without Z3210 installed), About 8.2 hr. (with Z3210 installed and wireless communications active)
- Communication interface : USB Bluetooth® wireless communications (when Z3210 installed)
FEATURES
- Battery measurement can be performed while the battery is connected to its host device, without taking it offline
- Measure and save data in as fast as 2 seconds, a 60% improvement from the legacy 3554
- Instantaneously diagnose battery degradation (PASS, WARNING, FAIL) by measuring internal resistance and voltage (*1)
- Noise reduction technology improves noise resistance
- Screen and audio (*2) guidance simplifies measurement
- Measurement data is linked to site information and saved, reducing management man-hours
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross (*3) or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- New protector delivers better ergonomic hold and durability in the field.
SKU: n/a -
EARTH RESISTANCE TESTER
HIOKI FT-6031-50 Earth Tester
SPECIFICATIONS
- Measurement System : Two-electrode method/three-electrode method (switchable)
- Measurement range / Accuracy :
20 Ω (0 Ω〜20.00 Ω) / ±1.5% rdg ±8 dgt
200 Ω (0 Ω〜200.0 Ω) / ±1.5% rdg ±4 dgt
2000 Ω (0 Ω〜2000 Ω) / ±1.5% rdg ±4 dgt - Earth voltage : 0〜30.0 V rms
Accuracy : ±2.3% rdg ±8 dgt (50 Hz/60 Hz), ±1.3% rdg ±4 dgt (DC) - Allowable earth potential : 25.0 V rms (DC or sine wave)
- Dustproof and waterproof : IP65/IP67 (EN60529)
- Dimensions : 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D
- Mass : 570 g (20.1 oz.) (including batteries and protector, excluding terminal covers and other accessories)
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Excellent noise resistance
- IP67 protected – top of the industry
- Minimize cabling time with innovative earthing rods and cable winder
- Wide 0Ω to 2000Ω measurement range
- Test all ground types from Class A to Class D with a single meter
SKU: n/a -
DIGITAL INSULATION TESTER
HIOKI IR-3455 High Voltage Ins…
SPECIFICATIONS
- Test Voltage : 250 V to 5.00 kV DC, (Possible in 25 V steps between 250 V and 1 kV and in 100 V steps between 1 and 5 kV)
- Measurement Range :
0.00 MΩ to 500 GΩ (250 V)
0.00 MΩ to 1.00 TΩ (500 V)
0.00 MΩ to 2.00 TΩ (1 kV)
0.00 MΩ to 5.00 TΩ (2.5 kV)
0.00 MΩ to 10.0 TΩ (5 kV) - Measurement Current : 1 mA (Test voltage 250 V to 1.00 kV), 0.5 mA (Test voltage 1.10 kV to 2.50 kV) 0.25 mA (Test voltage 2.60 kV to 5.00 kV), Short-circuit current: 2 mA or less
- Resistance Range : 10 MΩ to 10 TΩ, 7 ranges (auto range)
- Accuracy :
±5% rdg. ±5 dgt. Up to [Test voltage (setting value)/Resistance measurable at 100 nA]
±20% rdg. ±5 dgt. [Test voltage (setting value)/Resistance measurable at 100 nA] to [Test voltage (setting value)/Resistance measurable at 1 nA] or 500 GΩ
±30% rdg. ±50 dgt. [Test voltage (setting value)/Resistance measurable at 1 nA] or 501 GΩ to 9.99 TΩ - Leakage current measurement : 1.00 nA to 1.20 mA, 6 ranges (current measurement that occurs when test voltage is generated)
Accuracy ±2.5% rdg. ±5 dgt. (1 mA range); refer to complete catalog for other ranges - Voltage measurement : ±50 V to ±1.00 kV DC, 50 V to 750 V AC (50/60 Hz),
Accuracy: ±5 % rdg. ±5 dgt. , Input resistance: Approx. 10 MΩ - Temperature measurement : -10.0 ˚C to 70.0 ˚C, 3 ranges (used with optional sensor)
Accuracy ±1.0 ˚C (0.0 ˚C to 40.0 ˚C); refer to complete catalog for other ranges - Other Functions : Insulation Diagnosis (Temperature compensation, PI/DAR display, Step voltage test), Data memory, Communication (USB 2.0, PC application software), auto discharge, hot conductor warning indication, etc.
- Digital LCD, max. 999 dgt. with backlight, Bar graph display
- Dimensions and Mass : 260 mm (10.24 in)W × 250.6 mm (9.87 in)H × 119.5 mm (4.70 in)D, 2.8 kg (98.8 oz)
- Included Accessories : Test lead 9750-01 ×1, Test lead 9750-02 ×1, Test lead 9750-03 ×1, Alligator clip 9751-01 ×1, Alligator clip 9751-02 ×1, Alligator clip 9751-03 ×1, Instruction manual ×1, LR6 (AA) alkaline batteries ×6, USB cable ×1, PC application software (CD-R) ×1
FEATURES
- Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
- Wide testing voltage range, up to 5.00 kV from 250 V DC
- Wide measurement insulation range, up to 10 TΩ
- PI (Polarization Index) and DAR (Dielectric Absorption Ratio) automatically calculated / display
- Extended operating temperature range of -10°C to 50°C
- Data memory function to reduce handwritten notes
- Bright LED luminous scale
SKU: n/a -
PROBES
HIOKI P2000 DC High Voltage Pr…
SPECIFICATIONS
- Maximum Input Voltage : DC 2000 V
- Maximum rated line-to-ground voltage
1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V - Input Resistance : 20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open)
- Overload Protection :
2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) - Output Terminal : 4 mm banana terminal
- Operating Temperature Range : -25°C to 65°C (-13°F to 149°F)
- Operating Humidity Range : −25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing)
40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing) - Storage temperature and humidity range : -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing)
- Standards : EN 61010
- Included Accessories : Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1
FEATURES
- Enables high voltage measurement up to CAT Ⅲ 2000 V
- Safely measure solar installations like the mega-solar without interrupting the grid
- Connects to compatible Hioki clamp meters and digital multimeters (DMMs)
ACCURACY FOR COMPATIBLE INSTRUMENTS
- DT-4261 :
Range 600.0 V: Combined accuracy ±0.5% rdg ±0.2 V
Range 2000 V: Combined accuracy ±0.5% rdg ±5 V - CM4141-50 ; CM4371-50 ; CM4373-50 ; CM4375-50 :
Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V
Range 2000 V: Combined accuracy ±1.0% rdg ±3 V - DT-4282 ; DT-4281 :
Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10)
Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10) - DT-4252 ; DT-4253 :
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10) - DT-4255 ; DT-4256 :
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10)
SKU: n/a