Lutron AQ-9901SDThe device is designed to measure air quality – it also measures CO, CO2, O2 levels, temperature and dew point. The measured data is recorded on an SD card in Excel format, where it can be further processed. The instrument can also be used as an indicator, and it also has the option of setting an alarm – a warning sound signal when the defined value is exceeded.
CO2 AND HUMIDITY METER
LUTRON CO and CO2 meter AQ-9901SD
SPECIFICATIONS
- Circuit : Custom one-chip of microprocessor LSI circuit.
- Display : LCD size : 52 mm x 38 mm ; LCD with green backlight ( ON/OFF ).
- Measurement :
CO2 (Carbon dioxide )
CO ( Carbon monoxide )
O2 ( Oxygen in air )
Humidity
Dew point Temp., Wet bulb Temp. - Data error number : 0.1% of total saved data max.
- Memory Card : SD memory card. 1 GB to 16 GB.
- Sampling time of display : Approx. 1 second.
- Power Supply : AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.
ELECTRICAL SPECIFICATIONS
- CO2 ( Carbon dioxide )
Range : 0 to 4,000 ppm
Resolution : 1 ppm
Accuracy : ± 40 ppm : 1,000 ppm ; ± 5% of reading : > 1,000 ppm 3,000 ppm ; ± 250 ppm typically : > 3,000 ppm, reference only - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
- CO ( Carbon dioxide )
Range : 0 to 1,000 ppm
Resolution : 1 ppm
Accuracy : ± ( 5% + 2 ppm )
Response Time : < 30 seconds
Sensitivity Drift : < 5% per year - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
- O2 ( Air oxygen )
Range : 0 to 30 %O2.
Resolution : 0.1 %O2.
Accuracy : ± ( 1 % reading + 0.2 % O2 )
Response Time : <= 15 seconds
Sensitivity Drift : < 5% per year
Overload Protection : 100 %O2.
Environment Pressure Range : 0.9 to 1.1 atmosphere. - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
FEATURES
- RS232/USB computer interface.
- Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional .
- Separate probe, easy for remote measurements.
- Complete set of 4 probes : CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe,Humidity/Temp. probe, main meter and the hard carrying case.
- Sampling time for data recorder is 2 seconds to 8 hours
- Alarm setting with the beeper sound output
- Humidity sensor : Precision capacitance sensor
- CO, O2 sensor : Galvanic cell type.
- CO range : 0 to 1,000 ppm x 1 ppm
- O2 range : 0 to 30.0 % x 0.1 %.
- CO2 range : 0 to 4,000 ppm x 1 ppm.